Simple Guide to Configuring Hot Water Circulation Pump
This simple guide will show you how to easily configure a hot water circulation pump to run periodically for 3 minutes in 30-minute intervals during the day, providing instant hot water for washing.
Output Configuration
-
Navigate to the TapHome output module.
-
Set the relevant output where the circulation pump is connected as Pulse-width modulation .
-
Select Device type “Circulation pump ” and save the settings.
-
Go to the newly created Circulation pump device and set
PWMPeriodto 1800s (30 minutes) in the Service settings menu.
Automation
- Add a Smart rule Lighting timer .
- Set the motion sensor to Presence from the Presence sensor.
- Press Configure to limit it only to non-night times - 07:00 - 22:00.
- Set Execute Action to Circulation pump → Power 10% (i.e., 3 minutes out of 30 minutes is on, since it’s a PWM output).
- For a specified time - can be left unchanged.